{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T17:12:37.932","vulnerabilities":[{"cve":{"id":"CVE-2021-33729","sourceIdentifier":"productcert@siemens.com","published":"2021-10-12T10:15:12.060","lastModified":"2024-11-21T06:09:27.753","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a V1.0 SP2 Update 1). Un atacante autenticado que sea capaz de importar contenedores de firmware a un sistema afectado podría ejecutar comandos arbitrarios en la base de datos local"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0","matchCriteriaId":"2B59D696-F272-40DA-8DC6-423D9E5026C0"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*","matchCriteriaId":"4ED13FC8-63C0-42C6-A51C-C480C45327C2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*","matchCriteriaId":"E68FE047-8F53-46B8-82D4-9342B1C8CA55"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:1.0:sp2:*:*:*:*:*:*","matchCriteriaId":"5F2C66EC-5A29-4B92-AEDB-7DB8A5CA7391"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}