{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T05:02:24.951","vulnerabilities":[{"cve":{"id":"CVE-2021-33609","sourceIdentifier":"security@vaadin.com","published":"2021-10-13T11:15:07.133","lastModified":"2024-11-21T06:09:11.490","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Missing check in DataCommunicator class in com.vaadin:vaadin-server versions 8.0.0 through 8.14.0 (Vaadin 8.0.0 through 8.14.0) allows authenticated network attacker to cause heap exhaustion by requesting too many rows of data."},{"lang":"es","value":"Una falta de comprobación en la clase DataCommunicator en com.vaadin:vaadin-server versiones 8.0.0 hasta 8.14.0 (Vaadin 8.0.0 hasta 8.14.0) permite a un atacante de red autenticado causar el agotamiento de la pila al solicitar demasiadas filas de datos"}],"metrics":{"cvssMetricV31":[{"source":"security@vaadin.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:N/I:N/A:P","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"security@vaadin.com","type":"Secondary","description":[{"lang":"en","value":"CWE-400"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:vaadin:vaadin:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0.0","versionEndExcluding":"8.14.1","matchCriteriaId":"B87713FE-14F4-4A75-B880-795A7CDABA69"}]}]}],"references":[{"url":"https://github.com/vaadin/framework/pull/12415","source":"security@vaadin.com","tags":["Patch","Third Party Advisory"]},{"url":"https://vaadin.com/security/cve-2021-33609","source":"security@vaadin.com","tags":["Vendor Advisory"]},{"url":"https://github.com/vaadin/framework/pull/12415","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"]},{"url":"https://vaadin.com/security/cve-2021-33609","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}