{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-26T04:06:17.635","vulnerabilities":[{"cve":{"id":"CVE-2021-33058","sourceIdentifier":"secure@intel.com","published":"2021-11-17T20:15:09.793","lastModified":"2026-06-17T03:54:04.803","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Improper access control in the installer Intel(R)Administrative Tools for Intel(R) Network Adaptersfor Windowsbefore version 1.4.0.21 may allow an unauthenticated user to potentially enable escalation of privilege via local access."},{"lang":"es","value":"Un control de acceso inapropiado en el instalador Herramientas administrativas de Intel(R) para adaptadores de red de Intel para Windows versiones anteriores a 1.4.0.21, puede permitir a un usuario no autenticado habilitar potencialmente una escalada de privilegios por medio de un acceso local."}],"affected":[{"source":"secure@intel.com","affectedData":[{"vendor":"n/a","product":"version","versions":[{"version":"before version 1.4.0.21","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","baseScore":4.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:intel:administrative_tools_for_intel_network_adapters:*:*:*:*:*:windows:*:*","versionEndExcluding":"1.4.0.21","matchCriteriaId":"5648E6E0-83A1-464B-8E9B-C3D2C49743F5"}]}]}],"references":[{"url":"https://security.netapp.com/advisory/ntap-20211210-0005/","source":"secure@intel.com","tags":["Third Party Advisory"]},{"url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00555.html","source":"secure@intel.com","tags":["Vendor Advisory"]},{"url":"https://security.netapp.com/advisory/ntap-20211210-0005/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00555.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}