{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-05T02:48:39.324","vulnerabilities":[{"cve":{"id":"CVE-2021-31518","sourceIdentifier":"security@trendmicro.com","published":"2021-05-05T15:15:08.460","lastModified":"2024-11-21T06:05:50.590","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Trend Micro Home Network Security 6.5.599 and earlier is vulnerable to a file-parsing vulnerability which could allow an attacker to exploit the vulnerability and cause a denial-of-service to the device. This vulnerability is similar, but not identical to CVE-2021-31517."},{"lang":"es","value":"Trend Micro Home Network Security versiones 6.5.599 y anteriores, es susceptible a una vulnerabilidad de análisis de archivos que podría permitir a un atacante explotar la vulnerabilidad y causar una denegación de servicio en el dispositivo.&#xa0;Esta vulnerabilidad es similar, pero no idéntica a CVE-2021-31517"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:home_network_security:*:*:*:en:*:*:*:*","versionEndIncluding":"6.5.599","matchCriteriaId":"D2A6C520-2F92-4DD2-85C0-110BA87E5792"},{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:home_network_security:*:*:*:ja:*:*:*:*","versionEndIncluding":"6.5.599","matchCriteriaId":"1DD965FE-1066-4C12-BB31-FC5B536A8050"},{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:home_network_security:*:*:*:zh:*:*:*:*","versionEndIncluding":"6.5.599","matchCriteriaId":"F53D6A33-030D-44C0-9E05-98BF50B7F1E0"}]}]}],"references":[{"url":"https://helpcenter.trendmicro.com/en-us/article/TMKA-10312","source":"security@trendmicro.com","tags":["Vendor Advisory"]},{"url":"https://helpcenter.trendmicro.com/en-us/article/TMKA-10312","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}