{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-30T08:08:26.894","vulnerabilities":[{"cve":{"id":"CVE-2021-31338","sourceIdentifier":"productcert@siemens.com","published":"2021-08-19T16:15:12.243","lastModified":"2024-11-21T06:05:26.833","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Client (Todas las versiones anteriores a V3.0 SP1). Los dispositivos afectados permiten modificar los ajustes de configuración a través de un canal no autenticado. Esto podría permitir a un atacante local escalar privilegios y ejecutar código propio en el dispositivo."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","baseScore":4.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-15"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect:*:*:*:*:*:*:*:*","versionEndExcluding":"3.0","matchCriteriaId":"9EE01078-3C5D-4BF9-9939-5692FF11F30A"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect:3.0:-:*:*:*:*:*:*","matchCriteriaId":"1F2BC5B5-429F-4C8F-ACCE-E544868F3A88"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-816035.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-816035.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}