{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T07:44:18.912","vulnerabilities":[{"cve":{"id":"CVE-2021-29297","sourceIdentifier":"cve@mitre.org","published":"2021-07-30T19:15:09.127","lastModified":"2024-11-21T06:00:56.460","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Buffer Overflow in Emerson GE Automation Proficy Machine Edition v8.0 allows an attacker to cause a denial of service and application crash via crafted traffic from a Man-in-the-Middle (MITM) attack to the component \"FrameworX.exe\" in the module \"MSVCR100.dll\"."},{"lang":"es","value":"Un desbordamiento del búfer en Emerson GE Automation Proficy Machine Edition versión v8.0, permite a un atacante causar una denegación de servicio y un bloqueo de la aplicación por medio de tráfico diseñado desde un ataque Man-in-the-Middle (MITM) al componente \"FrameworX.exe\" en el módulo \"MSVCR100.dll\""}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:H/Au:N/C:N/I:N/A:P","baseScore":2.6,"accessVector":"NETWORK","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"LOW","exploitabilityScore":4.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-120"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:emerson:proficy_machine_edition:8.0:*:*:*:*:*:*:*","matchCriteriaId":"94670572-48FA-43D2-B59D-D8965C355854"}]}]}],"references":[{"url":"https://github.com/boofish/GE_Proficy_Machine_Edition_vul","source":"cve@mitre.org","tags":["Broken Link","Third Party Advisory"]},{"url":"https://github.com/boofish/GE_Proficy_Machine_Edition_vul/blob/main/vul1/vul1_steps.pdf","source":"cve@mitre.org","tags":["Broken Link","Third Party Advisory"]},{"url":"https://github.com/boofish/GE_Proficy_Machine_Edition_vul","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link","Third Party Advisory"]},{"url":"https://github.com/boofish/GE_Proficy_Machine_Edition_vul/blob/main/vul1/vul1_steps.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link","Third Party Advisory"]}]}}]}