{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-12T19:11:24.351","vulnerabilities":[{"cve":{"id":"CVE-2021-27274","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2021-03-29T21:15:13.187","lastModified":"2024-11-21T05:57:44.470","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MFileUploadController class. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-12124."},{"lang":"es","value":"Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de NETGEAR ProSAFE Network Management System versión 1.6.0.26.&#xa0;No es requerida una autenticación para explotar esta vulnerabilidad.&#xa0;El fallo específico se presenta dentro de la clase MFileUploadController.&#xa0;El problema resulta de una falta de comprobación apropiada de una ruta suministrada por el usuario antes de usarla en operaciones de archivos.&#xa0;Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de SYSTEM.&#xa0;Era ZDI-CAN-12124"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-434"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:netgear:prosafe_network_management_system:1.6.0.26:*:*:*:*:*:*:*","matchCriteriaId":"A2C1F32B-238F-4435-9229-345EB07DE7D2"}]}]}],"references":[{"url":"https://kb.netgear.com/000062688/Security-Advisory-for-Pre-Authentication-Command-Injection-on-NMS300-PSV-2020-0560","source":"zdi-disclosures@trendmicro.com","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-357/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://kb.netgear.com/000062688/Security-Advisory-for-Pre-Authentication-Command-Injection-on-NMS300-PSV-2020-0560","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-357/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}