{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-16T21:33:37.584","vulnerabilities":[{"cve":{"id":"CVE-2021-26577","sourceIdentifier":"security-alert@hpe.com","published":"2021-02-08T20:15:12.887","lastModified":"2024-11-21T05:56:31.140","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Baseboard Management Controller (BMC) firmware in HPE Apollo 70 System prior to version 3.0.14.0 has a local buffer overflow in libifc.so uploadsshkey function."},{"lang":"es","value":"El firmware de Baseboard Management Controller (BMC) en HPE Apollo 70 System versiones anteriores a 3.0.14.0, presenta un desbordamiento de búfer local en la función uploadsshkey de libifc.so"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-120"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:hpe:baseboard_management_controller:*:*:*:*:*:*:*:*","versionEndExcluding":"3.0.14.0","matchCriteriaId":"063FC3AB-012F-41B5-9442-1FC41C89FB8C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:hpe:apollo_70_system:-:*:*:*:*:*:*:*","matchCriteriaId":"7706B4E2-1ED1-4EDE-B134-9F5BE0B24499"}]}]}],"references":[{"url":"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf04080en_us","source":"security-alert@hpe.com","tags":["Patch","Vendor Advisory"]},{"url":"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf04080en_us","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}