{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T14:08:05.762","vulnerabilities":[{"cve":{"id":"CVE-2021-26262","sourceIdentifier":"20705f08-db8b-4497-8f94-7eea62317651","published":"2021-11-19T19:15:08.700","lastModified":"2026-04-02T14:16:20.727","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor."},{"lang":"es","value":"Philips MRI 1.5T y MRI 3T versión 5.x.x, no restringe o restringe incorrectamente el acceso a un recurso de un actor no autorizado"}],"metrics":{"cvssMetricV40":[{"source":"20705f08-db8b-4497-8f94-7eea62317651","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.9,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"20705f08-db8b-4497-8f94-7eea62317651","type":"Secondary","description":[{"lang":"en","value":"CWE-286"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:mri_3t_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.0.0","versionEndExcluding":"6.0.0","matchCriteriaId":"C6E28B57-F160-4463-A019-01C016729B87"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:mri_3t:-:*:*:*:*:*:*:*","matchCriteriaId":"D61A1A34-1132-47AC-9BBB-06537D59C9FA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:mri_1.5t_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.0.0","versionEndExcluding":"6.0.0","matchCriteriaId":"E7B195E6-DBA3-44A1-ACD4-4961F62C0B5C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:mri_1.5t:-:*:*:*:*:*:*:*","matchCriteriaId":"27C345BC-B71C-4EA3-A7FD-07354F2D9375"}]}]}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01","source":"20705f08-db8b-4497-8f94-7eea62317651","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","source":"20705f08-db8b-4497-8f94-7eea62317651","tags":["Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}