{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-03T19:08:27.083","vulnerabilities":[{"cve":{"id":"CVE-2021-22819","sourceIdentifier":"cybersecurity@se.com","published":"2022-01-28T20:15:10.407","lastModified":"2024-11-21T05:50:44.230","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"},{"lang":"es","value":"Una CWE-1021: Se presenta una vulnerabilidad de Restricción Inapropiada de las Capas o Marcos de la Interfaz de Usuario Renderizados que podría causar modificaciones no intencionadas de la configuración del producto o de las cuentas de usuario cuando es engañado al usuario para que use la interfaz web renderizada dentro de iframes. Productos afectados: EVlink City EVC1S22P4 / EVC1S7P4 (Todas las versiones anteriores a R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (Todas las versiones anteriores a R8 V3.4.0.2), y EVlink Smart Wallbox EVB1A (Todas las versiones anteriores a R8 V3.4.0.2)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-1021"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"B642A170-59F4-428B-9FEC-9D45B893A049"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*","matchCriteriaId":"AA9F3DA4-C027-4210-8A2B-87121373CE60"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"7D8FCC53-5F49-46E7-8E09-B4D271258F37"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*","matchCriteriaId":"C224B6C5-BCA4-400A-A50E-017843825356"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"E1D75184-6377-4421-AE11-68DE965E1DD8"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*","matchCriteriaId":"58F33653-E41D-499A-BD44-0D294C003D7B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"5567B0DB-F9E6-4FD1-8FEF-ACB454688C52"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*","matchCriteriaId":"B266B002-6C10-4E0B-B14C-9C0A55070CD8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_parking_evp2pe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"D9E650CC-B63E-4F7B-A0C3-97A0F8B34E58"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_parking_evp2pe:-:*:*:*:*:*:*:*","matchCriteriaId":"9F383E0A-DB07-40E9-B7F2-01E62044C1A4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.4.0.2","matchCriteriaId":"120B4CA0-FE37-457E-B476-795DA57E9169"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*","matchCriteriaId":"CC5D698C-6161-4F6D-94CE-01A0ECA95C47"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}