{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T15:14:01.981","vulnerabilities":[{"cve":{"id":"CVE-2021-22797","sourceIdentifier":"cybersecurity@se.com","published":"2022-04-13T16:15:09.370","lastModified":"2024-11-21T05:50:41.417","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)"},{"lang":"es","value":"Una CWE-22: Se presenta una vulnerabilidad de Limitación inadecuada de un nombre de ruta a un directorio restringido (\" Salto de Ruta\") que podría causar la implementación de scripts maliciosos en una ubicación no autorizada y puede resultar en una ejecución de código en la estación de trabajo de ingeniería cuando es cargado un archivo de proyecto malicioso en el software de ingeniería. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"8DCC0C29-32C2-4463-B98F-AB4B56FF5314"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"2021","matchCriteriaId":"FAB4A9EC-96A2-424D-A858-162E662EBEFB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*","matchCriteriaId":"3FFDF36B-30A5-4B35-956C-60DC15CE7EE4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*","matchCriteriaId":"F51A7887-4F1A-428C-9E68-260E7262A678"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*","matchCriteriaId":"58BACC54-6609-4DCE-AEEC-A9C2396635A0"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*","matchCriteriaId":"FFDF44F3-2514-4CB0-A1A4-87123225B0F1"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*","matchCriteriaId":"4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*","matchCriteriaId":"DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-257-01/","source":"cybersecurity@se.com","tags":["Mitigation","Patch","Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-257-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}