{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T00:05:48.856","vulnerabilities":[{"cve":{"id":"CVE-2021-22794","sourceIdentifier":"cybersecurity@se.com","published":"2022-04-13T16:15:09.257","lastModified":"2024-11-21T05:50:41.060","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"},{"lang":"es","value":"Una CWE-22: Se presenta una vulnerabilidad de Limitación de un Nombre de Ruta a un Directorio Restringido (\"Salto de Ruta \") que podría causar una ejecución de código remota. Producto afectado: StruxureWare Data Center Expert (versiones V7.8.1 y anteriores)"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.3,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*","versionEndIncluding":"7.8.1","matchCriteriaId":"D7773EA4-29BE-4527-A5E6-5271C15D8F60"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}