{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T14:24:13.268","vulnerabilities":[{"cve":{"id":"CVE-2021-22784","sourceIdentifier":"cybersecurity@se.com","published":"2021-07-21T15:15:15.377","lastModified":"2024-11-21T05:50:39.650","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."},{"lang":"es","value":"A CWE-306: Se presenta una vulnerabilidad de Falta de Autentificación para una Función Crítica en C-Bus Toolkit versiones v1.15.8 y anteriores, que podría permitir a un atacante usar una página web diseñada para obtener acceso remoto al sistema"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N","baseScore":5.7,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.1,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:S/C:N/I:P/A:N","baseScore":3.5,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":6.8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*","versionEndExcluding":"1.15.9","matchCriteriaId":"3B18E52F-DE56-4B3B-8E11-52DC57650C38"}]}]}],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04","source":"cybersecurity@se.com","tags":["Product","Vendor Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2021-50","source":"cybersecurity@se.com","tags":["Exploit","Third Party Advisory"]},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product","Vendor Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2021-50","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}