{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T13:05:40.763","vulnerabilities":[{"cve":{"id":"CVE-2021-22768","sourceIdentifier":"cybersecurity@se.com","published":"2021-06-11T16:15:10.663","lastModified":"2024-11-21T05:50:37.770","vulnStatus":"Modified","cveTags":[{"sourceIdentifier":"cybersecurity@se.com","tags":["unsupported-when-assigned"]}],"descriptions":[{"lang":"en","value":"A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767"},{"lang":"es","value":"** NO COMPATIBLE CUANDO SE ASIGNÓ ** UN CWE-20: Se presenta una vulnerabilidad de comprobación inapropiada de la entrada en PowerLogic EGX100 (versiones 3.0.0 y posteriores) y PowerLogic EGX300 (todas las versiones) que podría causar una denegación de servicio o una ejecución de código remota por medio de un paquete HTTP especialmente diseñado. Este ID de CVE es diferente de CVE-2021-22767"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_egx100_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0.0","matchCriteriaId":"29A55C4C-0D14-4C55-ABBC-83280E221DE3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_egx100:-:*:*:*:*:*:*:*","matchCriteriaId":"FE28A3BC-AD07-48F1-9DB9-65616A9399B5"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_egx300_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"9CB9B239-F219-4DF4-B53B-4DCE38F3205F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_egx300:-:*:*:*:*:*:*:*","matchCriteriaId":"59A033CD-1DBC-44A4-9C56-1F97C3F40C6F"}]}]}],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}