{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T02:54:02.007","vulnerabilities":[{"cve":{"id":"CVE-2021-22736","sourceIdentifier":"cybersecurity@se.com","published":"2021-05-26T20:15:09.093","lastModified":"2024-11-21T05:50:33.743","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized file is uploaded."},{"lang":"es","value":"Se presenta una vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta a un Directorio Restringido (\"Salto de Ruta\") en homeLYnk (Wiser para KNX) y spaceLYnk  versiones V2.60 y anteriores, que podría causar una denegación de servicio cuando un archivo no autorizado es cargado"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.0","matchCriteriaId":"317276F1-1B80-4CBC-92A0-8F1E7561FA16"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*","matchCriteriaId":"F7B2FBBD-C461-47EF-A912-E445C063DED9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:homelynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.0","matchCriteriaId":"5E04856B-1BBF-4E36-BB26-4E03F603F645"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:homelynk:-:*:*:*:*:*:*:*","matchCriteriaId":"E5369C17-DEC4-4B14-ACFB-6CCCB6C04F1D"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}