{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-30T04:01:07.315","vulnerabilities":[{"cve":{"id":"CVE-2021-22717","sourceIdentifier":"cybersecurity@se.com","published":"2021-04-13T19:15:14.303","lastModified":"2024-11-21T05:50:31.323","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."},{"lang":"es","value":"Una CWE-22: Se presenta una vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta para un Directorio Restringido (\"Path Traversal\") en C-Bus Toolkit (versiones V1.15.7 y anteriores) que podría permitir una  ejecución de código remota al procesar archivos de configuración"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*","versionEndIncluding":"1.15.7","matchCriteriaId":"F0CC2C60-78DD-4959-B70F-CF0A3073FC56"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-447/","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-447/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}