{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-08T14:12:19.828","vulnerabilities":[{"cve":{"id":"CVE-2021-22665","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2021-03-18T18:15:13.450","lastModified":"2024-11-21T05:50:26.157","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system."},{"lang":"es","value":"DriveTools SP versiones v5.13 y anteriores de Rockwell Automation y Drives AOP versiones v4.12 y anteriores, contienen una vulnerabilidad que un atacante local con privilegios limitados puede ser capaz de explotar, resultando en una escalada de privilegios y un control completo del sistema"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-427"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:drivetools_add-on_profiles:*:*:*:*:*:*:*:*","versionEndIncluding":"4.12","matchCriteriaId":"2052E441-B61E-42A6-B263-E6FCF5A30B7B"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:drivetools_sp:*:*:*:*:*:*:*:*","versionEndIncluding":"5.13","matchCriteriaId":"1DF300A1-CD1E-46A4-A114-EC030F30CF7D"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1129798","source":"ics-cert@hq.dhs.gov","tags":["Permissions Required","Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-042-02","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1129798","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-042-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}