{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T23:30:35.106","vulnerabilities":[{"cve":{"id":"CVE-2021-22289","sourceIdentifier":"cybersecurity@ch.abb.com","published":"2022-08-11T15:15:09.587","lastModified":"2024-11-21T05:49:51.273","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code."},{"lang":"es","value":"Una vulnerabilidad de comprobación de entrada inapropiada en el mecanismo de carga de proyectos en versiones posteriores a 4.0 incluyéndola, de B&amp;R Automation Studio puede permitir que un atacante de red no autenticado ejecute código"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@ch.abb.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":8.3,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@ch.abb.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:br-automation:studio:*:*:*:*:*:*:*:*","versionStartIncluding":"4.0","matchCriteriaId":"757BAACA-7C75-453A-8122-4EF24FC9F7B2"}]}]}],"references":[{"url":"https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf","source":"cybersecurity@ch.abb.com","tags":["Vendor Advisory"]},{"url":"https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}