{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T17:15:05.008","vulnerabilities":[{"cve":{"id":"CVE-2021-21883","sourceIdentifier":"talos-cna@cisco.com","published":"2021-12-22T19:15:09.123","lastModified":"2024-11-21T05:49:10.447","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An OS command injection vulnerability exists in the Web Manager Diagnostics: Ping functionality of Lantronix PremierWave 2050 8.9.0.0R4. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."},{"lang":"es","value":"Se presenta una vulnerabilidad de inyección de comandos en el Sistema Operativo en la funcionalidad Diagnostics: Ping del Administrador Web de Lantronix PremierWave versión 2050 8.9.0.0R4. Una petición HTTP especialmente diseñada puede conllevar a una ejecución de un comando arbitrario. Un atacante puede realizar una petición HTTP autenticada para desencadenar esta vulnerabilidad"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.1,"impactScore":6.0}],"cvssMetricV30":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.1,"impactScore":6.0}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"talos-cna@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:lantronix:premierwave_2050_firmware:8.9.0.0:r4:*:*:*:*:*:*","matchCriteriaId":"C0160E0B-2A30-4E5C-BC9D-FB059D24BB93"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:lantronix:premierwave_2050:-:*:*:*:*:*:*:*","matchCriteriaId":"18D68E19-E0E6-4102-A973-814686E4EC82"}]}]}],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1327","source":"talos-cna@cisco.com","tags":["Exploit","Technical Description","Third Party Advisory"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1327","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Technical Description","Third Party Advisory"]}]}}]}