{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-28T14:10:39.521","vulnerabilities":[{"cve":{"id":"CVE-2021-0104","sourceIdentifier":"secure@intel.com","published":"2021-06-09T20:15:08.713","lastModified":"2024-11-21T05:41:51.250","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Uncontrolled search path element in the installer for the Intel(R) Rapid Storage Technology software, before versions 17.9.0.34, 18.0.0.640 and 18.1.0.24, may allow an authenticated user to potentially enable escalation of privilege via local access."},{"lang":"es","value":"Un elemento de ruta de búsqueda no controlado en el instalador del software Intel® Rapid Storage Technology, versiones anteriores a 17.9.0.34, 18.0.0.640 y 18.1.0.24, puede permitir a un usuario autenticado permitir potencialmente una escalada de privilegios por medio de un acceso local"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:P/I:P/A:P","baseScore":4.4,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.4,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-427"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:intel:rapid_storage_technology:*:*:*:*:*:*:*:*","versionEndExcluding":"17.9.1.1009.5","matchCriteriaId":"3E8575D4-697C-4427-B068-3D6BB0F76C30"},{"vulnerable":true,"criteria":"cpe:2.3:a:intel:rapid_storage_technology:*:*:*:*:*:*:*:*","versionStartIncluding":"18.0.0.640","versionEndExcluding":"18.0.3.1148.4","matchCriteriaId":"AC743601-07C0-4073-A5DA-5D8120DB9A91"},{"vulnerable":true,"criteria":"cpe:2.3:a:intel:rapid_storage_technology:*:*:*:*:*:*:*:*","versionStartIncluding":"18.1.0.24","versionEndExcluding":"18.1.0.1028.2","matchCriteriaId":"37147309-2AE5-42BE-9387-8C19D543C324"}]}]}],"references":[{"url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00545.html","source":"secure@intel.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00545.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}