{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T23:16:40.637","vulnerabilities":[{"cve":{"id":"CVE-2020-8603","sourceIdentifier":"security@trendmicro.com","published":"2020-05-27T23:15:11.167","lastModified":"2024-11-21T05:39:06.647","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A cross-site scripting vulnerability (XSS) in Trend Micro InterScan Web Security Virtual Appliance 6.5 may allow a remote attacker to tamper with the web interface of affected installations. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file."},{"lang":"es","value":"Una vulnerabilidad de tipo cross-site scripting (XSS) en Trend Micro InterScan Web Security Virtual Appliance versión 6.5, puede permitir a un atacante remoto alterar la interfaz web de las instalaciones afectadas. Es requerida una interacción del usuario para explotar esta vulnerabilidad, en el que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:interscan_web_security_virtual_appliance:6.5:*:*:*:*:*:*:*","matchCriteriaId":"1173BDF5-ADEB-49D5-B5B9-A911AF171179"}]}]}],"references":[{"url":"https://success.trendmicro.com/solution/000253095","source":"security@trendmicro.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-675/","source":"security@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://success.trendmicro.com/solution/000253095","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-675/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}