{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T00:32:54.607","vulnerabilities":[{"cve":{"id":"CVE-2020-7590","sourceIdentifier":"productcert@siemens.com","published":"2020-10-13T16:15:21.780","lastModified":"2024-11-21T05:37:25.887","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en DCA Vantage Analyzer (todas las versiones anteriores a V4.5 están afectadas por CVE-2020-7590. Además, los números de serial anteriores a 40000 que ejecutan el software versión V4.4.0 también están afectadas por CVE-2020-15797).&#xa0;Los dispositivos afectados usan una contraseña embebida para proteger la base de datos integrada.&#xa0;Esto podría permitir a un atacante leer o modificar la base de datos integrada.&#xa0;Una explotación con éxito requiere acceso físico directo al dispositivo"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","baseScore":4.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-259"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:dca_vantage_analyzer_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.5.0.0","matchCriteriaId":"2B4F34A3-AB7B-4528-9F27-3073E25A5176"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:dca_vantage_analyzer:-:*:*:*:*:*:*:*","matchCriteriaId":"EDE5221F-8629-4DC4-AD8A-93EED671469B"}]}]}],"references":[{"url":"https://www.siemens-healthineers.com/support-documentation/security-advisory","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://www.siemens-healthineers.com/support-documentation/security-advisory","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}