{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-22T19:31:59.535","vulnerabilities":[{"cve":{"id":"CVE-2020-7524","sourceIdentifier":"cybersecurity@se.com","published":"2020-08-31T17:15:12.453","lastModified":"2026-06-17T03:24:56.487","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal."},{"lang":"es","value":"Se presenta una vulnerabilidad de Escritura Fuera de Límites en Modicon M218 Logic Controller (versiones V5.0.0.7 y anteriores) que podría causar una Denegación de Servicio al enviar un paquete IPV4 específico diseñado hacia el controlador: Envío de un paquete de protocolo IPv4 específico hacia Schneider Electric Modicon M218 Logic Controller puede causar que los dispositivos IPv4 se caigan. El dispositivo no funciona apropiadamente y debe volver a encenderse para volver a la normalidad"}],"affected":[{"source":"cybersecurity@se.com","affectedData":[{"vendor":"n/a","product":"Modicon M218 Logic Controller V5.0.0.7 and prior","versions":[{"version":"Modicon M218 Logic Controller V5.0.0.7 and prior","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m218_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"5.0.0.7","matchCriteriaId":"F031868A-65CC-4803-9777-1C1B7B79BF08"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m218:-:*:*:*:*:*:*:*","matchCriteriaId":"852DBDD1-E960-4D87-9F77-8B8CB94222BB"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-224-03/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-224-03/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}