{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-28T14:51:20.873","vulnerabilities":[{"cve":{"id":"CVE-2020-7500","sourceIdentifier":"cybersecurity@se.com","published":"2020-06-16T20:15:14.863","lastModified":"2024-11-21T05:37:16.007","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause arbitrary code to be executed when a malicious command is entered."},{"lang":"es","value":"Una CWE-89: Se presenta una vulnerabilidad de Neutralización Inapropiada de Elementos Especiales utilizados en un Comando SQL (\"SQL Injection'') en U.motion Servers and Touch Panels  (versiones afectadas listadas en la notificación de seguridad) lo cual podrían causar una ejecución de código arbitraria cuando un comando malicioso es ingresado"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6501-0001_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"B0B3DF18-FE18-4465-8223-8AF2B286746D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6501-0001:-:*:*:*:*:*:*:*","matchCriteriaId":"22E79A6F-C946-43A7-B492-7F3F8CFB18CC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6501-0002_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"CF40C8EB-9735-43D5-A947-087EFE6AF6F8"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6501-0002:-:*:*:*:*:*:*:*","matchCriteriaId":"4B17C76A-749C-44DA-8144-51E4328C4768"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6260-0410_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"AB0811DB-2E4D-4A14-8F87-2C24189D352A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6260-0410:-:*:*:*:*:*:*:*","matchCriteriaId":"7D91BDED-9BCF-473A-AB1B-824AA1EDE586"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6260-0415_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"E369B5A4-1F69-48C1-8C07-0E7C61683EDA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6260-0415:-:*:*:*:*:*:*:*","matchCriteriaId":"436B2EB8-6D93-41FF-BD6E-932D69C4E197"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6260-0310_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"0176D45B-9007-4558-8D72-B56454EB9733"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6260-0310:-:*:*:*:*:*:*:*","matchCriteriaId":"F046097B-B818-4775-A53D-B22F258CB255"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:mtn6260-0315_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.2","matchCriteriaId":"FD29EA41-FA54-45A7-BB61-76D6B1CEF5C4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:mtn6260-0315:-:*:*:*:*:*:*:*","matchCriteriaId":"9DD21D34-FBBD-4645-8C60-42825281D0FE"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-133-03/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-133-03/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}