{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T18:05:37.897","vulnerabilities":[{"cve":{"id":"CVE-2020-7494","sourceIdentifier":"cybersecurity@se.com","published":"2020-06-16T20:15:14.380","lastModified":"2024-11-21T05:37:15.360","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file."},{"lang":"es","value":"Una CWE-22: Se presenta una vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta en un Directorio Restringido (\"Path Traversal\") en EcoStruxure Operator Terminal Expert versiones 3.1 Service Pack 1 y anteriores (anteriormente conocido como Vijeo XD) que podría causar una ejecución de código malicioso cuando se abre el archivo del proyecto"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*","versionEndIncluding":"3.0","matchCriteriaId":"9E274928-428F-4CD4-9EF6-7C499B4FBCBA"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.1:-:*:*:*:*:*:*","matchCriteriaId":"C5B39FB1-D76F-47E9-AA10-E32282202F04"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.1:sp1:*:*:*:*:*:*","matchCriteriaId":"DC9E5C58-B3D1-4871-A63D-0E48E747C610"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-133-04","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-133-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}