{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T14:28:51.686","vulnerabilities":[{"cve":{"id":"CVE-2020-7478","sourceIdentifier":"cybersecurity@se.com","published":"2020-03-23T20:15:12.370","lastModified":"2024-11-21T05:37:13.563","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled."},{"lang":"es","value":"Una CWE-22: Se presenta una Limitación Inapropiada de un Nombre de Ruta a un Directorio Restringido en IGSS (Versiones 14 y anteriores al uso del servicio: IGSSupdate), lo que podría permitir a un atacante remoto no autenticado leer archivos arbitrarios desde la PC del servidor IGSS en una red sin restricciones o compartida cuando el IGSS Update Service está habilitado."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0","versionEndExcluding":"14.0.0.20009","matchCriteriaId":"A6131D00-9397-4EE5-A369-004DEEC8AC5F"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}