{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T16:57:52.184","vulnerabilities":[{"cve":{"id":"CVE-2020-6967","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2020-03-23T21:15:12.207","lastModified":"2024-11-21T05:36:24.250","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data."},{"lang":"es","value":"En Rockwell Automation, todas las versiones del software FactoryTalk Diagnostics, un subsistema de la FactoryTalk Services Platform, FactoryTalk Diagnostics expone un endpoint .NET Remoting por medio del archivo RNADiagnosticsSrv.exe en TCPtcp/8082, lo cual puede deserializar de forma no segura los datos no confiables."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-502"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-502"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:-:*:*:*:*:*:*:*","matchCriteriaId":"DD8A46F8-B6B4-4F58-AD35-3C9DACEA4F16"}]}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-051-02","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-051-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}