{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-26T11:17:52.492","vulnerabilities":[{"cve":{"id":"CVE-2020-6091","sourceIdentifier":"talos-cna@cisco.com","published":"2020-05-22T14:15:12.107","lastModified":"2026-06-17T03:22:40.280","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An exploitable authentication bypass vulnerability exists in the ESPON Web Control functionality of Epson EB-1470Ui MAIN: 98009273ESWWV107 MAIN2: 8X7325WWV303. A specially crafted series of HTTP requests can cause authentication bypass resulting in information disclosure. An attacker can send an HTTP request to trigger this vulnerability."},{"lang":"es","value":"Se presenta una vulnerabilidad de omisión de autenticación explotable en la funcionalidad ESPON Web Control de Epson EB-1470Ui MAIN: 98009273ESWWV107 MAIN2: 8X7325WWV303. Una serie especialmente diseñada de peticiones HTTP puede causar una omisión de autenticación, resultando en una divulgación de información. Un atacante puede enviar una petición HTTP para activar esta vulnerabilidad."}],"affected":[{"source":"talos-cna@cisco.com","affectedData":[{"vendor":"n/a","product":"Epson","versions":[{"version":"Epson EB-1470Ui MAIN: 98009273ESWWV107 MAIN2: 8X7325WWV303","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":5.2}],"cvssMetricV30":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:N","baseScore":6.4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"talos-cna@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-288"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:epson:eb-1470ui_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"BF0D2F95-2B8B-40E7-BC71-5E5F475CF4B3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:epson:eb-1470ui:-:*:*:*:*:*:*:*","matchCriteriaId":"3E9C519E-0D7E-469A-8AFB-F93EABD62F86"}]}]}],"references":[{"url":"https://epson.com/support/wa00907","source":"talos-cna@cisco.com"},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2020-1011","source":"talos-cna@cisco.com","tags":["Third Party Advisory"]},{"url":"https://epson.com/support/wa00907","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2020-1011","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}