{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-14T08:15:18.572","vulnerabilities":[{"cve":{"id":"CVE-2020-5944","sourceIdentifier":"f5sirt@f5.com","published":"2020-11-05T20:15:17.817","lastModified":"2024-11-21T05:34:52.697","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In BIG-IQ 7.1.0, accessing the DoS Summary events and DNS Overview pages in the BIG-IQ system interface returns an error message due to disabled Grafana reverse proxy in web service configuration. F5 has done further review of this vulnerability and has re-classified it as a defect. CVE-2020-5944 will continue to be referenced in F5 Security Advisory K57274211 and will not be assigned to other F5 vulnerabilities."},{"lang":"es","value":"En BIG-IQ versión 7.1.0, el acceso a los eventos de DoS Summary y las páginas de DNS Overview en la interfaz del sistema BIG-IQ devuelve un mensaje de error debido a que el proxy inverso de Grafana está desactivado en la configuración del servicio web. F5 ha hecho un examen más detallado de esta vulnerabilidad y la ha reclasificado como un defecto. CVE-2020-5944 continuará siendo referenciado en el F5 Security Advisory K57274211 y no será asignado a otras vulnerabilidades del F5"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:N/I:N/A:P","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:f5:big-iq_centralized_management:*:*:*:*:*:*:*:*","versionStartIncluding":"7.1.0","versionEndExcluding":"7.1.0.1","matchCriteriaId":"E9A6F5B2-11FC-4B1E-AB67-E6CAFDD3F72F"}]}]}],"references":[{"url":"https://support.f5.com/csp/article/K57274211","source":"f5sirt@f5.com","tags":["Vendor Advisory"]},{"url":"https://support.f5.com/csp/article/K57274211","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}