{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-16T19:14:37.697","vulnerabilities":[{"cve":{"id":"CVE-2020-5797","sourceIdentifier":"vulnreport@tenable.com","published":"2020-11-21T06:15:12.537","lastModified":"2024-11-21T05:34:36.923","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"UNIX Symbolic Link (Symlink) Following in TP-Link Archer C9(US)_V1_180125 firmware allows an unauthenticated actor, with physical access and network access, to read sensitive files and write to a limited set of files after plugging a crafted USB drive into the router."},{"lang":"es","value":"Un Seguimiento Enlace Simbólico de UNIX (Symlink) en TP-Link Archer versiones de firmware C9(EE. UU.) _V1_180125, permite a un actor no autenticado, con acceso físico y acceso de red, leer archivos confidenciales y escribir en un conjunto limitado de archivos después de conectar una unidad USB diseñada en el enrutador"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":0.9,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:N","baseScore":3.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-59"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:archer_c9_firmware:180125:*:*:*:*:*:*:*","matchCriteriaId":"FCDD6D05-37DF-4762-85B8-1CB49DBF3E90"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:archer_c9:v1:*:*:*:*:*:*:*","matchCriteriaId":"AE0C00A1-F050-4CF3-86A4-310145909DF2"}]}]}],"references":[{"url":"https://www.tenable.com/security/research/tra-2020-60","source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2020-60","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}