{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T02:05:21.569","vulnerabilities":[{"cve":{"id":"CVE-2020-5726","sourceIdentifier":"vulnreport@tenable.com","published":"2020-03-30T20:15:20.180","lastModified":"2024-11-21T05:34:29.507","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the CTI server on port 8888. A remote unauthenticated attacker can invoke the challenge action with a crafted username and discover user passwords."},{"lang":"es","value":"La serie Grandstream UCM6200 versiones anteriores a 1.0.20.22, es vulnerable a una inyección SQL por medio del servidor CTI en el puerto 8888. Un atacante no autenticado remoto puede invocar la acción challenge con un nombre de usuario diseñado y detectar las contraseñas de usuarios."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"vulnreport@tenable.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","matchCriteriaId":"F55C1906-9C0D-4479-B545-059329485BCD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:grandstream:ucm6202:-:*:*:*:*:*:*:*","matchCriteriaId":"9864BD0F-BE9C-4F72-AB57-77036699029B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","matchCriteriaId":"2D9A2414-684F-4C61-BCAC-E7967A7BFF2B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:grandstream:ucm6204:-:*:*:*:*:*:*:*","matchCriteriaId":"B5A26ABB-8BED-4E61-91AA-ABF1B90CBD81"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","matchCriteriaId":"3164240C-6CAB-4433-8EB3-5F09552A7F4D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:grandstream:ucm6208:-:*:*:*:*:*:*:*","matchCriteriaId":"EA744718-8862-4579-B9CF-E1E8137A02E6"}]}]}],"references":[{"url":"http://packetstormsecurity.com/files/156977/Grandstream-UCM6200-Series-CTI-Interface-SQL-Injection.html","source":"vulnreport@tenable.com"},{"url":"https://www.tenable.com/security/research/tra-2020-17","source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory"]},{"url":"http://packetstormsecurity.com/files/156977/Grandstream-UCM6200-Series-CTI-Interface-SQL-Injection.html","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.tenable.com/security/research/tra-2020-17","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}