{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T10:38:00.948","vulnerabilities":[{"cve":{"id":"CVE-2020-3376","sourceIdentifier":"psirt@cisco.com","published":"2020-07-31T00:15:12.913","lastModified":"2024-11-21T05:30:54.563","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability in the Device Manager application of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions on an affected device. The vulnerability is due to a failure in the software to perform proper authentication. An attacker could exploit this vulnerability by browsing to one of the hosted URLs in Cisco DCNM. A successful exploit could allow the attacker to interact with and use certain functions within the Cisco DCNM."},{"lang":"es","value":"Una vulnerabilidad en la aplicación Device Manager de Cisco Data Center Network Manager (DCNM), podría permitir a un atacante remoto no autenticado omitir la autenticación y ejecutar acciones arbitrarias sobre un dispositivo afectado. La vulnerabilidad es debido a un fallo en el software para llevar a cabo una autenticación apropiada. Un atacante podría explotar esta vulnerabilidad al buscar una de las URL alojadas en Cisco DCNM. Una explotación con éxito podría permitir al atacante interactuar y usar determinadas funciones dentro del Cisco DCNM"}],"metrics":{"cvssMetricV31":[{"source":"psirt@cisco.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":3.9,"impactScore":3.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"psirt@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:data_center_network_manager:11.0\\(1\\):*:*:*:*:*:*:*","matchCriteriaId":"D727159F-04FE-4AC6-83AB-AC93A58E937E"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:data_center_network_manager:11.1\\(1\\):*:*:*:*:*:*:*","matchCriteriaId":"AE3F4588-58F0-4C6D-A8CC-B9F5CDD24A3E"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:data_center_network_manager:11.2\\(1\\):*:*:*:*:*:*:*","matchCriteriaId":"9E1815B5-E810-4E4A-8EA7-0F4527824A49"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:data_center_network_manager:11.3\\(1\\):*:*:*:*:*:*:*","matchCriteriaId":"7EB871C9-CA14-4829-AED3-CC2B35E99E92"}]}]}],"references":[{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-dcnm-auth-bypass-JkubGpu3","source":"psirt@cisco.com","tags":["Vendor Advisory"]},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-dcnm-auth-bypass-JkubGpu3","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}