{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-10-03T00:32:16.658","vulnerabilities":[{"cve":{"id":"CVE-2020-29030","sourceIdentifier":"VulnerabilityReporting@secomea.com","published":"2021-03-05T21:15:12.687","lastModified":"2026-06-17T03:11:00.510","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4."},{"lang":"es","value":"Una vulnerabilidad de tipo Cross-Site Request Forgery (CSRF) en la GUI web de Secomea GateManager, permite a un atacante ejecutar código malicioso.&#xa0;Este problema afecta a: Secomea GateManager Todas las versiones anteriores a 9.4"}],"affected":[{"source":"VulnerabilityReporting@secomea.com","affectedData":[{"vendor":"Secomea","product":"GateManager","versions":[{"version":"All","lessThan":"9.4","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"VulnerabilityReporting@secomea.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.2},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"VulnerabilityReporting@secomea.com","type":"Secondary","description":[{"lang":"en","value":"CWE-352"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-352"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:secomea:gatemanager_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"9.4.621054022","matchCriteriaId":"00395298-44A2-46C2-8CBA-B87A8954C58A"}]}]}],"references":[{"url":"https://www.secomea.com/support/cybersecurity-advisory/","source":"VulnerabilityReporting@secomea.com","tags":["Vendor Advisory"]},{"url":"https://www.secomea.com/support/cybersecurity-advisory/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}