{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T02:09:24.095","vulnerabilities":[{"cve":{"id":"CVE-2020-28398","sourceIdentifier":"productcert@siemens.com","published":"2024-12-10T14:15:18.320","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to \r\ncross-site request forgery (CSRF).\r\n\r\nThis could allow an attacker to read or modify the device configuration\r\nby tricking an authenticated legitimate user into accessing a malicious link."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en RUGGEDCOM ROX MX5000 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX MX5000RE (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1400 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1500 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1501 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1510 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1511 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1512 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1524 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1536 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1536 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1540 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1550 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1560 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1570 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1580 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1600 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1610 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX1620 (Todas las versiones &lt; V2.16.0), RUGGEDCOM ROX RX16 V2.16.0), RUGGEDCOM ROX RX5000 (todas las versiones anteriores a V2.16.0). La función CLI en la interfaz web de los dispositivos afectados es vulnerable a cross-site request forgery (CSRF). Esto podría permitir que un atacante lea o modifique la configuración del dispositivo engañando a un usuario legítimo autenticado para que acceda a un enlace malicioso."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-352"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-384652.html","source":"productcert@siemens.com"}]}}]}