{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T23:52:03.998","vulnerabilities":[{"cve":{"id":"CVE-2020-28384","sourceIdentifier":"productcert@siemens.com","published":"2021-01-12T21:15:17.917","lastModified":"2024-11-21T05:22:41.630","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP12), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP2). Las aplicaciones afectadas carecen de una comprobación apropiada de los datos proporcionados por el usuario al analizar archivos PAR. Esto podría conllevar a un desbordamiento del búfer en la región stack de la memoria. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*","versionEndExcluding":"se2020","matchCriteriaId":"7AF39DFE-A31B-4324-BB62-0B446ACA04B7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*","matchCriteriaId":"07440B76-B975-4946-8A97-38C564D240E4"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*","matchCriteriaId":"5F0A748E-BB6F-4604-8024-F50DC0C20EAF"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*","matchCriteriaId":"F4F37267-6B37-46A4-B9F9-4264BEC922D1"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*","matchCriteriaId":"CB1DC54B-E715-4425-B6B6-900F2CFBCE03"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*","matchCriteriaId":"2F495722-39BD-4BA1-A643-C7D0BA81CC21"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*","matchCriteriaId":"7B776512-BF3D-4F70-BD58-AFF8E1B03EE2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*","matchCriteriaId":"99E05299-50FD-4292-9978-8E05C1483FE2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*","matchCriteriaId":"2447D05B-2634-4895-B7B0-6F7DBB9D2EC2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*","matchCriteriaId":"CBBD39F3-790F-4017-A57E-6EFC314F0557"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*","matchCriteriaId":"B4387BFA-8A98-433E-9EF7-B29226C195A7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*","matchCriteriaId":"9E380F66-C11C-472B-9B71-7CB4AF4FABDC"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*","matchCriteriaId":"0CF4ACE1-B069-4007-8142-7F90015BBE9D"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*","matchCriteriaId":"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*","matchCriteriaId":"49F5649A-349C-42C6-AFFF-CEE1ABC14E67"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04","source":"productcert@siemens.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-055/","source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-076/","source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-055/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-076/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}