{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-11T01:36:39.412","vulnerabilities":[{"cve":{"id":"CVE-2020-27541","sourceIdentifier":"cve@mitre.org","published":"2021-01-26T18:15:46.177","lastModified":"2024-11-21T05:21:20.367","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Denial of Service vulnerability in Rostelecom CS-C2SHW 5.0.082.1. AgentGreen service has a bug in parsing broadcast discovery UDP packet. Sending a packet of too small size will lead to an attempt of allocating buffer of negative size. As the result service AgentGreen will be terminated and started again later."},{"lang":"es","value":"Una vulnerabilidad de Denegación de Servicio en Rostelecom CS-C2SHW versión 5.0.082.1.&#xa0;El servicio AgentGreen presenta un error al analizar el paquete UDP de detección de difusión.&#xa0;El envío de un paquete de tamaño demasiado pequeño conllevará a un intento de asignar un búfer de tamaño negativo.&#xa0;Como resultado, el servicio AgentGreen se terminará y se reiniciará más tarde"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:company:cs-c2shw_firmware:5.0.082.1:*:*:*:*:*:*:*","matchCriteriaId":"DA2108A4-A3BF-4ECE-99E7-9EE9233063EB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:company:cs-c2shw:-:*:*:*:*:*:*:*","matchCriteriaId":"C1CC4768-6258-44B3-9290-AF21DDB6E728"}]}]}],"references":[{"url":"https://dil4rd.medium.com/groundhog-day-in-iot-valley-or-5-cves-in-1-camera-7dc1d2864707","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://dil4rd.medium.com/groundhog-day-in-iot-valley-or-5-cves-in-1-camera-7dc1d2864707","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}