{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-16T22:35:09.197","vulnerabilities":[{"cve":{"id":"CVE-2020-27253","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2020-11-26T02:15:12.183","lastModified":"2024-11-21T05:20:56.927","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device."},{"lang":"es","value":"Se presenta un fallo en la rutina de comprobación de Ingresos y Egresos de FactoryTalk Linx Versiones 6.11 y anteriores.&#xa0;Esta vulnerabilidad podría permitir a un atacante remoto, no autenticado, diseñar específicamente un paquete malicioso resultando en una condición de denegación de servicio en el dispositivo"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*","versionEndIncluding":"6.11","matchCriteriaId":"89622117-4485-4204-A5DA-B72F7F13D353"}]}]}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}