{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T18:31:06.866","vulnerabilities":[{"cve":{"id":"CVE-2020-27150","sourceIdentifier":"vulnerability@kaspersky.com","published":"2021-05-14T12:15:07.777","lastModified":"2024-11-21T05:20:47.077","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In multiple versions of NPort IA5000A Series, the result of exporting a device’s configuration contains the passwords of all users on the system and other sensitive data in the original form if “Pre-shared key” doesn’t set."},{"lang":"es","value":"En múltiples versiones de la Serie NPort IA5000A, el resultado de exportar la configuración de un dispositivo contiene las contraseñas de todos los usuarios del sistema y otros datos confidenciales en el formato original si no es ajustado \"Pre-shared key\""}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5150a_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.4","matchCriteriaId":"E529D705-C625-4FFC-AC48-FE2CFE32922D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5150a:-:*:*:*:*:*:*:*","matchCriteriaId":"EBA01711-3023-4961-872F-5DB4792C13C3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5250a_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.4","matchCriteriaId":"AD9AF3B1-D1A2-450C-9D29-30CC95DAC558"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5250a:-:*:*:*:*:*:*:*","matchCriteriaId":"4C7805EF-B929-4DB3-9D68-FEBCD0B69781"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5450a_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.7","matchCriteriaId":"3575CF6C-0E61-4527-8D8B-F7C7A46F0FAC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5450a:-:*:*:*:*:*:*:*","matchCriteriaId":"D377FBAC-FF5B-4DFB-9ECA-4D148AFE0CDE"}]}]}],"references":[{"url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2021/05/11/klcert-20-019%2C","source":"vulnerability@kaspersky.com"},{"url":"https://www.moxa.com/en/support/product-support/security-advisory/nport-ia5000a-serial-device-servers-vulnerabilities","source":"vulnerability@kaspersky.com","tags":["Vendor Advisory"]},{"url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2021/05/11/klcert-20-019%2C","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.moxa.com/en/support/product-support/security-advisory/nport-ia5000a-serial-device-servers-vulnerabilities","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}