{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T22:58:14.928","vulnerabilities":[{"cve":{"id":"CVE-2020-27149","sourceIdentifier":"vulnerability@kaspersky.com","published":"2021-05-14T12:15:07.730","lastModified":"2024-11-21T05:20:46.977","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed."},{"lang":"es","value":"Al explotar una vulnerabilidad en la Serie NPort IA5150A/IA5250A versiones anteriores a 1.5, un usuario con nivel de privilegio \"Read Only\" puede enviar peticiones mediante la consola web para cambiar la configuración del dispositivo"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:N/I:P/A:N","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5150a_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.5","matchCriteriaId":"EFE57EA1-1AA4-41A8-BDFE-723B31F56DC0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5150a:-:*:*:*:*:*:*:*","matchCriteriaId":"EBA01711-3023-4961-872F-5DB4792C13C3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5250a_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.5","matchCriteriaId":"56FC63E7-98DF-437C-8A73-F5728F3C794E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5250a:-:*:*:*:*:*:*:*","matchCriteriaId":"4C7805EF-B929-4DB3-9D68-FEBCD0B69781"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:moxa:nport_ia5450a_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.0","matchCriteriaId":"F911D1EE-2963-46D3-AEC4-2EFDDC5469F5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:moxa:nport_ia5450a:-:*:*:*:*:*:*:*","matchCriteriaId":"D377FBAC-FF5B-4DFB-9ECA-4D148AFE0CDE"}]}]}],"references":[{"url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2021/05/11/klcert-20-018%2C","source":"vulnerability@kaspersky.com"},{"url":"https://www.moxa.com/en/support/product-support/security-advisory/nport-ia5000a-serial-device-servers-vulnerabilities","source":"vulnerability@kaspersky.com","tags":["Vendor Advisory"]},{"url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2021/05/11/klcert-20-018%2C","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.moxa.com/en/support/product-support/security-advisory/nport-ia5000a-serial-device-servers-vulnerabilities","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}