{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T00:09:32.408","vulnerabilities":[{"cve":{"id":"CVE-2020-27009","sourceIdentifier":"productcert@siemens.com","published":"2021-04-22T21:15:09.220","lastModified":"2024-11-21T05:20:40.473","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones anteriores a V5.2), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados). La funcionalidad de descompresión de registros de nombres de dominio DNS no valida correctamente los valores de desplazamiento del puntero. El análisis sintáctico de respuestas malformadas podría dar lugar a una escritura más allá del final de una estructura asignada. Un atacante con una posición privilegiada en la red podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual o provocar una condición de denegación de servicio"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-823"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*","versionEndExcluding":"5.2","matchCriteriaId":"7AA3D291-7974-459E-8629-82EEE9222881"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*","matchCriteriaId":"53A38C64-612A-4BC5-83D5-D3FA1C90E0F7"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}