{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-24T04:48:04.770","vulnerabilities":[{"cve":{"id":"CVE-2020-27002","sourceIdentifier":"productcert@siemens.com","published":"2021-02-09T17:15:14.077","lastModified":"2024-11-21T05:20:39.743","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12043)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0.2), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0.2). Las aplicaciones afectadas carecen de una comprobación apropiada de los datos suministrados por el usuario al analizar archivos PAR. Esto podría resultar en un acceso a la memoria más allá del final de un búfer asignado.. Un atacante podría aprovechar esta vulnerabilidad para acceder a los datos en el contexto del proceso actual.. (ZDI-CAN-12043)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:N","baseScore":3.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"13.1.0.2","matchCriteriaId":"662917EE-CC9D-4BFC-B87B-97AB81C68DB8"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionEndExcluding":"13.1.0.2","matchCriteriaId":"94F3C436-4C43-4B3E-B7CD-A4938926E255"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-228/","source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-228/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}