{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T03:33:37.849","vulnerabilities":[{"cve":{"id":"CVE-2020-26997","sourceIdentifier":"productcert@siemens.com","published":"2021-04-22T21:15:09.187","lastModified":"2024-11-21T05:20:39.163","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP14), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de la validación adecuada de los datos suministrados por el usuario al analizar los archivos PAR. Esto podría dar lugar a desviaciones de puntero de un valor obtenido de una fuente no fiable. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-11919)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-822"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2020:*:*:*:*:*:*:*:*","versionEndIncluding":"se2020mp13","matchCriteriaId":"FF72CFDF-0F35-434F-9BBC-181B6CD98086"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2021:*:*:*:*:*:*:*:*","versionEndExcluding":"se2021mp14","matchCriteriaId":"48EE7B47-BED5-4D33-8D1F-913267DDBA12"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06","source":"productcert@siemens.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}