{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-03T23:51:27.130","vulnerabilities":[{"cve":{"id":"CVE-2020-26994","sourceIdentifier":"productcert@siemens.com","published":"2021-01-12T21:15:17.510","lastModified":"2024-11-21T05:20:38.840","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PCX files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0). Las aplicaciones afectadas carecen de una comprobación apropiada de los datos proporcionados por el usuario al analizar archivos PCX. Esto podría resultar en un desbordamiento del búfer en la región heap de la memoria. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"13.1.0","matchCriteriaId":"307FDFE4-A801-4978-8903-BC38ED035927"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionEndExcluding":"13.1.0","matchCriteriaId":"30E90A52-9FD9-450A-8003-9F6C451E0823"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}