{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T23:36:43.543","vulnerabilities":[{"cve":{"id":"CVE-2020-26075","sourceIdentifier":"psirt@cisco.com","published":"2020-11-18T18:15:11.637","lastModified":"2024-11-21T05:19:10.853","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to gain access to the back-end database of an affected device. The vulnerability is due to insufficient input validation of REST API requests that are made to an affected device. An attacker could exploit this vulnerability by crafting malicious API requests to the affected device. A successful exploit could allow the attacker to gain access to the back-end database of the affected device."},{"lang":"es","value":"Una vulnerabilidad en la API REST de Cisco IoT Field Network Director (FND), podría permitir a un atacante remoto autenticado obtener acceso a la base de datos del back-end de un dispositivo afectado.&#xa0;La vulnerabilidad es debido a una validación de entrada insuficiente de las peticiones de la API REST que se realizan a un dispositivo afectado.&#xa0;Un atacante podría explotar esta vulnerabilidad al diseñar peticiones de la API maliciosas para el dispositivo afectado.&#xa0;Una explotación con éxito podría permitirle al atacante obtener acceso a la base de datos del back-end del dispositivo afectado"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"psirt@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":3.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"psirt@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*","versionEndExcluding":"4.6.1","matchCriteriaId":"0D507A4F-4079-4B68-997E-88901E063348"}]}]}],"references":[{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-SQL-zEkBnL2h","source":"psirt@cisco.com","tags":["Vendor Advisory"]},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-SQL-zEkBnL2h","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}