{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T09:04:17.594","vulnerabilities":[{"cve":{"id":"CVE-2020-25241","sourceIdentifier":"productcert@siemens.com","published":"2021-03-15T17:15:20.097","lastModified":"2024-11-21T05:17:44.600","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en la familia SIMATIC MV400 (todas las versiones anteriores a V7.0.6).&#xa0;La pila TCP subyacente de los productos afectados no comprueba correctamente el número de secuencia de los paquetes TCP RST entrantes.&#xa0;Un atacante podría explotar esto para terminar sesiones de TCP arbitrarias"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1\/AV:N\/AC:L\/PR:N\/UI:N\/S:U\/C:N\/I:N\/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N\/AC:L\/Au:N\/C:N\/I:N\/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-1285"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-129"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv440_sr_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"F03A6447-DFB7-4D55-AB13-0605C222C24C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv440_sr:-:*:*:*:*:*:*:*","matchCriteriaId":"370D346E-9FD9-4BFC-A450-97F0903F7241"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv440_hr_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"47FE87FB-C8C3-4BA6-A482-41FA42061534"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv440_hr:-:*:*:*:*:*:*:*","matchCriteriaId":"3AF5BB67-B397-4B55-8C59-FADE42B31E56"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv440_ur_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"4E72C168-08E8-4C7D-9795-89C73EB320ED"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv440_ur:-:*:*:*:*:*:*:*","matchCriteriaId":"839BB322-A4DB-4E3F-9060-B07ED5009690"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv420_sr-b_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"D9A67233-D7EB-47B5-9816-E5FCE101A3CB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv420_sr-b:-:*:*:*:*:*:*:*","matchCriteriaId":"DC2379D7-FD2F-4A5D-B683-7F5CB73A17AE"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv420_sr-p_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"2FFB0530-86FE-49F6-BE38-D382FEA0779E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv420_sr-p:-:*:*:*:*:*:*:*","matchCriteriaId":"238F8700-C919-4210-B27C-19FBA946A154"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv420_sr-b_body_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"A8C5282A-1399-4197-BA56-0A569139627A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv420_sr-b_body:-:*:*:*:*:*:*:*","matchCriteriaId":"72F3CA3E-D578-4FD0-8405-FFAB566A3066"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_mv420_sr-p_body_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.0.6","matchCriteriaId":"DABCCAD5-8E21-4F7E-B0FF-C9AA44B88C04"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_mv420_sr-p_body:-:*:*:*:*:*:*:*","matchCriteriaId":"629016CC-4AE2-47B0-9662-00697C452737"}]}]}],"references":[{"url":"https:\/\/cert-portal.siemens.com\/productcert\/pdf\/ssa-599268.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https:\/\/cert-portal.siemens.com\/productcert\/pdf\/ssa-599268.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}