{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-13T19:56:21.663","vulnerabilities":[{"cve":{"id":"CVE-2020-17407","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2020-10-13T17:15:13.670","lastModified":"2024-11-21T05:08:02.070","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of Microhard Bullet-LTE prior to v1.2.0-r1112. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of authentication headers. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-10596."},{"lang":"es","value":"Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en instalaciones afectadas de Microhard Bullet-LTE versiones anteriores a v1.2.0-r1112.&#xa0;No es requerida una autenticación para explotar esta vulnerabilidad.&#xa0;El fallo específico se presenta dentro del manejo de los encabezados de autenticación.&#xa0;El problema resulta de una falta de comprobación apropiada de la longitud de los datos suministrados por el usuario antes de copiarlos hacia un búfer en la región stack de la memoria de longitud fija.&#xa0;Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de root.&#xa0;Fue ZDI-CAN-10596"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:microhardcorp:bullet-lte_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.0-r1112","matchCriteriaId":"8605BE32-A22B-4068-8962-F11F99ADFE12"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:microhardcorp:bullet-lte:-:*:*:*:*:*:*:*","matchCriteriaId":"C61D697C-C430-4E98-97F0-906F4481AB1F"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-1206/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-1206/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}