{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T10:54:28.858","vulnerabilities":[{"cve":{"id":"CVE-2020-15939","sourceIdentifier":"psirt@fortinet.com","published":"2021-09-06T16:15:07.373","lastModified":"2024-11-21T05:06:29.773","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An improper access control vulnerability (CWE-284) in FortiSandbox versions 3.2.1 and below and 3.1.4 and below may allow an authenticated, unprivileged attacker to download the device configuration file via the recovery URL."},{"lang":"es","value":"Una vulnerabilidad de control de acceso inapropiado (CWE-284) en FortiSandbox versiones 3.2.1 y por debajo y 3.1.4 y por debajo, puede permitir a un atacante autenticado y sin privilegios descargar el archivo de configuración del dispositivo por medio de la URL de recuperación."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisandbox:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1.5","matchCriteriaId":"BEFB39AD-4E58-4425-835E-B970C9319883"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisandbox:*:*:*:*:*:*:*:*","versionStartIncluding":"3.2.0","versionEndExcluding":"3.2.2","matchCriteriaId":"4492FB6E-8373-49EE-94D6-534B48731305"}]}]}],"references":[{"url":"https://fortiguard.com/advisory/FG-IR-20-071","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://fortiguard.com/advisory/FG-IR-20-071","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}