{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T00:32:58.712","vulnerabilities":[{"cve":{"id":"CVE-2020-14504","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2022-02-24T19:15:08.943","lastModified":"2025-04-17T19:15:50.580","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings."},{"lang":"es","value":"La interfaz web del módulo de comunicación 1734-AENTR maneja inapropiadamente la autenticación para las peticiones HTTP POST. Un atacante remoto no autenticado puede enviar una petición diseñada que puede permitir la modificación de los ajustes de configuración"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"4.001","versionEndIncluding":"4.005","matchCriteriaId":"DC7EE03C-DA81-40CC-B522-8483E5481DCB"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.011","versionEndIncluding":"5.017","matchCriteriaId":"593FCDBB-E5D0-4E57-B10C-3FA3C72CDD75"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b:-:*:*:*:*:*:*:*","matchCriteriaId":"EAD4BA02-28F4-4138-9E52-C12042DD997C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware:6.011:*:*:*:*:*:*:*","matchCriteriaId":"B44E467A-31EE-46BE-82AA-101C7C2EDC7A"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware:6.012:*:*:*:*:*:*:*","matchCriteriaId":"46D0F84C-6F68-4E2D-99AF-FA9E0682A24C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c:-:*:*:*:*:*:*:*","matchCriteriaId":"490F9ECB-1303-4457-9D20-8ADAC160AF6C"}]}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01","source":"ics-cert@hq.dhs.gov","tags":["Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Third Party Advisory","US Government Resource"]}]}}]}