{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-05T04:23:02.399","vulnerabilities":[{"cve":{"id":"CVE-2020-12817","sourceIdentifier":"psirt@fortinet.com","published":"2020-09-24T15:15:13.173","lastModified":"2024-11-21T05:00:20.053","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An improper neutralization of input vulnerability in FortiAnalyzer before 6.4.1 and 6.2.5 may allow a remote authenticated attacker to inject script related HTML tags via Name parameter of Storage Connectors."},{"lang":"es","value":"Una vulnerabilidad de neutralización inapropiada de la entrada en FortiAnalyzer versiones anteriores a 6.4.1 y 6.2.5, puede permitir a un atacante autenticado remoto inyectar etiquetas HTML relacionadas con script por medio del parámetro Name de Conectores de Almacenamiento."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:6.2.5:*:*:*:*:*:*:*","matchCriteriaId":"33BBFA56-466B-471F-AA74-0D8339CD2D6E"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:6.4.0:*:*:*:*:*:*:*","matchCriteriaId":"DA60D965-6F24-47E6-A62C-C147D51502A8"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:6.4.1:*:*:*:*:*:*:*","matchCriteriaId":"F00DF5B2-FA3D-478B-834D-9A64194215CA"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortitester:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","matchCriteriaId":"888CBB49-6E71-496E-AC1E-02A55F8E796A"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortitester:3.8.0:*:*:*:*:*:*:*","matchCriteriaId":"83A5237C-C126-4AEA-8CE8-DEC82DDEC69D"}]}]}],"references":[{"url":"https://fortiguard.com/advisory/FG-IR-20-054","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://fortiguard.com/advisory/FG-IR-20-054","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}