{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-04T03:40:36.062","vulnerabilities":[{"cve":{"id":"CVE-2020-10928","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2020-07-28T18:15:14.003","lastModified":"2024-11-21T04:56:23.313","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6700 V1.0.4.84_10.0.58 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of string table file uploads. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the web server. Was ZDI-CAN-9767."},{"lang":"es","value":"Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en las instalaciones afectadas de los enrutadores NETGEAR R6700 versión V1.0.4.84_10.0.58. No es requerida una autenticación para explotar esta vulnerabilidad. El fallo específico se presenta en el manejo de las cargas de archivos de tabla de cadenas. El problema resulta de una falta de comprobación apropiada de la longitud de los datos suministrados por el usuario antes de copiarlos en un búfer en la región heap de la memoria de longitud fija. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del servidor web. Fue ZDI-CAN-9767"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.5,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.5,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","baseScore":4.6,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r6700_firmware:1.0.4.84_10.0.58:*:*:*:*:*:*:*","matchCriteriaId":"617F5FF8-E0B6-4E1A-B568-911DC0A91297"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*","matchCriteriaId":"21B27F11-4262-4CE1-8107-B365A7C152F2"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-708/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-708/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}